Using the latest MDT/WDS: Workbench 6.3.8450.1000, WADK 10.1.17134.1
- imported a W10 x86 image (first x86 MDT image so far)
- built a task sequence for it, and is enabled. Task sequence's 'OS Info' shows it as x86.
- MDT Production share Properties: WinPE is set up for both x86 and x64.
Whenever I update or 'completely regenerate' the boot images, the x86 one always comes out with x64 architecture, which then prevents the x86 image from getting displayed.
Testing with the Build Lab's x86 boot image, it works fine, and shows the Build Lab's x86 image when booted with.
Edit: If it matters, the client hardware that the x86 image was initially grabbed from was 64-bit. Client also uses BIOS, not UEFI.